
181
Dran-View 6 User Guide
Time Range
The phasor determines the time-range to use for calculations in the following order:
1. If its parent is a DFT Chart, the same range as its parents will be used.
2. If its parent is an Event Details/Waveform Chart that contains an active
Area Marker, the range of the Area Marker is used.
3. If 2 is not the case, the time range of the active event is used (if this is a full
cycle).
4. If the range in 1 or 2 is not a full cycle, the starting-point is maintained and
the end-point is moved to the end of a full cycle after the starting point (if
there are enough waveforms available).
5. If there are any "gaps" or ranges with missing samples in the range now
determined, the starting-point is maintained and the end-point is moved to
the nearest full cycle ending before this gap.
6. If the range now determined does not equal at least one cycle, no data is
calculated.
Settings All settings for a phasor are available in its properties dialog box. To access this,
right-click on the phasor and select "Properties" from the pop-up menu.
Commenti su questo manuale